{"id":15065,"date":"2026-05-21T07:25:15","date_gmt":"2026-05-21T07:25:15","guid":{"rendered":"https:\/\/npt-lok.com\/?p=15065"},"modified":"2026-08-18T07:22:28","modified_gmt":"2026-08-18T07:22:28","slug":"needle-valve-types","status":"publish","type":"post","link":"https:\/\/npt-lok.com\/ja\/needle-valve-types","title":{"rendered":"\u30cb\u30fc\u30c9\u30eb\u30d0\u30eb\u30d6\u306e\u7a2e\u985e\u3068\u9078\u5b9a\u30ac\u30a4\u30c9"},"content":{"rendered":"<p><span style=\"font-weight: 400;\"><a href=\"https:\/\/npt-lok.com\/ja\/%e3%83%8b%e3%83%bc%e3%83%89%e3%83%ab%e3%83%90%e3%83%ab%e3%83%96\/\">\u30cb\u30fc\u30c9\u30eb\u30d0\u30eb\u30d6<\/a> are typically classified into several types, which are utilized for particular functions. And you may want to know what features you need to take into account when choosing one. Here is a brief introduction of each type and a selection guide.<\/span><\/p>\n<ol>\n<li><span style=\"font-weight: 400;\"> Main Types of Needle Valves<\/span><\/li>\n<\/ol>\n<p><b>Straight Needle Valve.\u00a0<\/b><\/p>\n<p><span style=\"font-weight: 400;\">This type of needle valve is the most general-purpose type of needle valve and is normally the first choice for the majority of applications as it is simple to use. The straight type of needle valve has an inlet connection and an outlet connection in a straight line.<\/span><\/p>\n<p><b>Angle type Needle Valve\u00a0<\/b><\/p>\n<p><span style=\"font-weight: 400;\">It has the inlet and outlet connection port angles of 90\u00b0. It can be mounted directly on a flat surface. It can also be recessed and installed flush with a panel.\u00a0 In many situations, such as those where space is at a premium, angle type needle valves can save a lot of space where the pipes are at right angles.<\/span><\/p>\n<p><a href=\"https:\/\/npt-lok.com\/ja\/%e9%ab%98%e5%9c%a7%e3%83%8b%e3%83%bc%e3%83%89%e3%83%ab%e3%83%90%e3%83%ab%e3%83%96\/\"><b>\u9ad8\u5727\u30cb\u30fc\u30c9\u30eb\u30d0\u30eb\u30d6<\/b><\/a><\/p>\n<p><span style=\"font-weight: 400;\">It is generally made of thick-walled materials, to withstand high pressure, and is commonly used in hydraulic systems, high pressure gas systems, and in the oil and gas field.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">It is also available in very small dimensions for use in instrument control panels, laboratory applications or as an additive to a chemical reactor. These precise control valves are available for very small flow rates of liquids or gases.<\/span><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-14518 aligncenter\" src=\"https:\/\/npt-lok.com\/wp-content\/uploads\/2026\/04\/S-6000-psi-needle-valve-3.png\" alt=\"6000 psi needle valve 3\" width=\"486\" height=\"486\" srcset=\"https:\/\/npt-lok.com\/wp-content\/uploads\/2026\/04\/S-6000-psi-needle-valve-3.png 486w, https:\/\/npt-lok.com\/wp-content\/uploads\/2026\/04\/S-6000-psi-needle-valve-3-150x150.png 150w, https:\/\/npt-lok.com\/wp-content\/uploads\/2026\/04\/S-6000-psi-needle-valve-3-12x12.png 12w\" sizes=\"auto, (max-width: 486px) 100vw, 486px\" \/><\/p>\n<p><b>Multi-port Needle Valve<\/b><\/p>\n<p><span style=\"font-weight: 400;\">It is designed with one inlet and two or three outlets. A multi-port needle valve is used to feed a pressure gauge, a pressure switch and a transmitter from one single process connection. This valve is very space saving on crowded panels.<\/span><\/p>\n<p><a href=\"https:\/\/npt-lok.com\/ja\/%e3%83%9e%e3%83%8b%e3%83%9b%e3%83%bc%e3%83%ab%e3%83%89%e3%83%90%e3%83%ab%e3%83%96\/\"><b>Manifold Needle Valve<\/b><\/a><\/p>\n<p><span style=\"font-weight: 400;\">It is a valve which contains one or more needle valves. They are offered in 2, 3 and 5 port variations. As the manifold type of valve is widely used in measurement applications, the manifolds are often used to connect a number of measurement points to one or more transmitters. In addition to the needle valves, manifold valves can also include block valves, equalizing and vent valves. The manifold type of valve has the advantage that less pipe work is required. The risk of leaks occurring is thus greatly reduced.<\/span><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-12510 aligncenter\" src=\"https:\/\/npt-lok.com\/wp-content\/uploads\/2023\/05\/5-way-manifold-valve.jpg\" alt=\"5\u65b9\u30de\u30cb\u30db\u30fc\u30eb\u30c9\u30d0\u30eb\u30d6\" width=\"370\" height=\"370\" srcset=\"https:\/\/npt-lok.com\/wp-content\/uploads\/2023\/05\/5-way-manifold-valve.jpg 370w, https:\/\/npt-lok.com\/wp-content\/uploads\/2023\/05\/5-way-manifold-valve-150x150.jpg 150w\" sizes=\"auto, (max-width: 370px) 100vw, 370px\" \/><\/p>\n<p>&nbsp;<\/p>\n<ol start=\"2\">\n<li><span style=\"font-weight: 400;\"> How to Choose the Right Needle Valve<\/span><\/li>\n<\/ol>\n<p><span style=\"font-weight: 400;\">When selecting a suitable needle valve for your particular sampling application there are several parameters that must be taken into account. These are as follows.<\/span><\/p>\n<p><b>Pressure rating<\/b><\/p>\n<p><span style=\"font-weight: 400;\">Needle valves are typically rated for higher pressures. These ratings are usually given for typical applications such as 3,000 psi, <a href=\"https:\/\/npt-lok.com\/ja\/6000psi%e3%83%8b%e3%83%bc%e3%83%89%e3%83%ab%e3%83%90%e3%83%ab%e3%83%96\/\">6,000 psi<\/a> \u307e\u305f\u306f <a href=\"https:\/\/npt-lok.com\/ja\/10000-psi-%e3%83%8b%e3%83%bc%e3%83%89%e3%83%ab%e3%83%90%e3%83%ab%e3%83%96\/\">10,000 psi<\/a>.\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 400;\">The rating of the needle valve must be equal to or greater than the system pressure. It will not harm the system if you choose a higher rating needle valve than required for the operating conditions of the system. However, a needle valve that is rated for a lower pressure than required for the operating conditions of the system could burst or leak.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">4,000 psi system: pick a 6,000 psi valve.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">System runs at 5,000 psi: pick 6,000 psi valve<\/span><\/p>\n<p><span style=\"font-weight: 400;\">An 8,000 psi system would require a 10,000 psi rated valve.<\/span><\/p>\n<p><span style=\"font-weight: 400;\"> <img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-11697 aligncenter\" src=\"https:\/\/npt-lok.com\/wp-content\/uploads\/2022\/09\/Pressure-Unit-Conversion.jpg\" alt=\"\u5727\u529b\u5358\u4f4d\u306e\u5909\u63db\" width=\"500\" height=\"500\" srcset=\"https:\/\/npt-lok.com\/wp-content\/uploads\/2022\/09\/Pressure-Unit-Conversion.jpg 500w, https:\/\/npt-lok.com\/wp-content\/uploads\/2022\/09\/Pressure-Unit-Conversion-150x150.jpg 150w\" sizes=\"auto, (max-width: 500px) 100vw, 500px\" \/><\/span><\/p>\n<p><b>Connection threads<\/b><\/p>\n<p><span style=\"font-weight: 400;\">Match the process connection threads to the needle valve body threads.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">NPT threads are commonly used in North America. They are tapered and are typically sealed with Teflon tape or pipe dope.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">BSP connections are most commonly used in Europe, Asia and the Middle East. Needle valves with BSP connections are available with tapered threads (BSPT) or with parallel threads (BSPP). It is essential that the customer clearly informs the supplier which type of connection is required.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Most OEMs use metric material and ports, particularly from European and Asian manufacturers.\u00a0<\/span><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-15025 aligncenter\" src=\"https:\/\/npt-lok.com\/wp-content\/uploads\/2026\/05\/C-One-Supplier-for-Three-Different-Thread-Standards.jpg\" alt=\"One Supplier for Three Different Thread Standards\" width=\"670\" height=\"380\" srcset=\"https:\/\/npt-lok.com\/wp-content\/uploads\/2026\/05\/C-One-Supplier-for-Three-Different-Thread-Standards.jpg 670w, https:\/\/npt-lok.com\/wp-content\/uploads\/2026\/05\/C-One-Supplier-for-Three-Different-Thread-Standards-18x10.jpg 18w\" sizes=\"auto, (max-width: 670px) 100vw, 670px\" \/><\/p>\n<p><b>\u6750\u6599<\/b><\/p>\n<p><span style=\"font-weight: 400;\">Needle valve bodies are made in a variety of materials, however the primary consideration for the body of the needle valve is to make it durable enough to resist corrosion and also to allow the needle valve to operate in very low temperatures.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">316 <a href=\"https:\/\/npt-lok.com\/ja\/%e3%82%b9%e3%83%86%e3%83%b3%e3%83%ac%e3%82%b9%e8%a3%bd%e3%83%8b%e3%83%bc%e3%83%89%e3%83%ab%e3%83%90%e3%83%ab%e3%83%96\/\">\u30b9\u30c6\u30f3\u30ec\u30b9\u92fc<\/a>: it is the general-purpose valve. Good corrosion-resistance, good temperature-range and generally adequate for all industrial applications.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">304 stainless steel: it has slightly lower cost than 316. A little less resistant to corrosion. For clean water, air or mild chemicals, it is a good, lower-cost alternative to 316.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Brass: it is for water, air, and low pressure only. Lower cost. Good for plumbing. Not for corrosive media or high temperatures.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Special alloys (Monel, Hastelloy, Inconel, Alloy 20, Duplex): They are for corrosive media, high temperatures, seawater, or sour gas. Expensive. Only needed if 316 stainless steel is not enough.<\/span><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-11662 aligncenter\" src=\"https:\/\/npt-lok.com\/wp-content\/uploads\/2022\/09\/Material-is-optional.jpg\" alt=\"\u7d20\u6750\u306f\u30aa\u30d7\u30b7\u30e7\u30f3\u3067\u3059\" width=\"370\" height=\"370\" srcset=\"https:\/\/npt-lok.com\/wp-content\/uploads\/2022\/09\/Material-is-optional.jpg 370w, https:\/\/npt-lok.com\/wp-content\/uploads\/2022\/09\/Material-is-optional-150x150.jpg 150w\" sizes=\"auto, (max-width: 370px) 100vw, 370px\" \/><\/p>\n<p><b>Packing material\u00a0<\/b><\/p>\n<p><span style=\"font-weight: 400;\">Packing encircles the stem. It is used to seal around the handle of the needle valve to prevent leakage.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">PTFE: Standard. Temperature range -54\u00b0C up to 200\u00b0C. Low friction, smooth operation. Suitable for most applications.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Graphite: Optional. Good from -50\u00b0C up to 570\u00b0C. Suitable for use with high temperature steam, hot oil or thermal fluid.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">If the process temperature is 200\u00b0C, PTFE would be the normal choice for this application as it is better than Graphite at lower temperatures. However, if the process temperature were to rise above 200\u00b0C then Graphite would be more suitable for this application.<\/span><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-15001 aligncenter\" src=\"https:\/\/npt-lok.com\/wp-content\/uploads\/2026\/05\/C-PTFE-or-Graphite-Packing-for-Needle-Valve-Pick-by-Your-Temperature-.jpg\" alt=\"PTFE or Graphite Packing for Needle Valve, Pick by Your Temperature\" width=\"670\" height=\"380\" srcset=\"https:\/\/npt-lok.com\/wp-content\/uploads\/2026\/05\/C-PTFE-or-Graphite-Packing-for-Needle-Valve-Pick-by-Your-Temperature-.jpg 670w, https:\/\/npt-lok.com\/wp-content\/uploads\/2026\/05\/C-PTFE-or-Graphite-Packing-for-Needle-Valve-Pick-by-Your-Temperature--18x10.jpg 18w\" sizes=\"auto, (max-width: 670px) 100vw, 670px\" \/><\/p>\n<p><b>Vent port or not<\/b><\/p>\n<p><span style=\"font-weight: 400;\">Standard needle valves are used to isolate an instrument, but when completely shut off, pressure on the instrument side of the needle valve is trapped. This can create problems when the instrument is removed from the needle valve as pressure is released with force through the opened up hole left by the removed instrument. Severe injury can result.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">A needle valve with a vent port can be opened up when closing the main valve of the needle valve. The small opening of the vent port then can release the pressurized fluid. The gauge then reads \u201c0\u201d and it is safe to remove your instrument without any spray of fluid.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Vent ports are recommended for applications where needle valves are used in front of pressure gauges or other pressure transmitting instruments (e.g. for monitoring pressure).<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Where to Go from Here<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Need to understand the basics first\uff1f Read <a href=\"https:\/\/npt-lok.com\/ja\/%e3%83%8b%e3%83%bc%e3%83%89%e3%83%ab%e3%83%90%e3%83%ab%e3%83%96%e3%81%a8%e3%81%af%e4%bd%95%e3%81%8b%e3%80%81%e3%81%9d%e3%81%97%e3%81%a6%e3%83%8b%e3%83%bc%e3%83%89%e3%83%ab%e3%83%90%e3%83%ab%e3%83%96\/\">What Is a Needle Valve and How It Works<\/a><\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Want to see where needle valves are used and get answers to common questions\uff1f Read <a href=\"https:\/\/npt-lok.com\/ja\/needle-valve-applications-and-faq\/\">Needle Valve Applications and FAQ<\/a><\/span><\/li>\n<\/ul>\n<div class=\"simg-pop-btn\" style=\"top: 3613.41px; left: 133.5px; display: none;\"><\/div>","protected":false},"excerpt":{"rendered":"<p>Needle valves are typically classified into several types, which are utilized for particular functions. And you may want to know what features you need to take into account when choosing one. Here is a brief introduction of each type and a selection guide. Main Types of Needle Valves Straight Needle Valve.\u00a0 This type of needle [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"default","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[1],"tags":[],"class_list":["post-15065","post","type-post","status-publish","format-standard","hentry","category-blog"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.7 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Needle valve types<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/npt-lok.com\/ja\/needle-valve-types\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Needle valve types\" \/>\n<meta property=\"og:description\" content=\"Needle valves are typically classified into several types, which are utilized for particular functions. And you may want to know what features you need to take into account when choosing one. Here is a brief introduction of each type and a selection guide. Main Types of Needle Valves Straight Needle Valve.\u00a0 This type of needle [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/npt-lok.com\/ja\/needle-valve-types\/\" \/>\n<meta property=\"og:site_name\" content=\"NPTLOK Instrumentation Tube Fittings and Valves\" \/>\n<meta property=\"article:published_time\" content=\"2026-05-21T07:25:15+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-08-18T07:22:28+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/npt-lok.com\/wp-content\/uploads\/2026\/04\/S-6000-psi-needle-valve-3.png\" \/>\n\t<meta property=\"og:image:width\" content=\"486\" \/>\n\t<meta property=\"og:image:height\" content=\"486\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"NPTLOK\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"NPTLOK\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"6\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/npt-lok.com\\\/needle-valve-types\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/npt-lok.com\\\/needle-valve-types\\\/\"},\"author\":{\"name\":\"NPTLOK\",\"@id\":\"https:\\\/\\\/npt-lok.com\\\/#\\\/schema\\\/person\\\/952fa6592fb0069202b037e7605d4e19\"},\"headline\":\"Needle Valve Types and Selection Guide\",\"datePublished\":\"2026-05-21T07:25:15+00:00\",\"dateModified\":\"2026-08-18T07:22:28+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/npt-lok.com\\\/needle-valve-types\\\/\"},\"wordCount\":1029,\"publisher\":{\"@id\":\"https:\\\/\\\/npt-lok.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/npt-lok.com\\\/needle-valve-types\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/npt-lok.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/S-6000-psi-needle-valve-3.png\",\"articleSection\":[\"Blog\"],\"inLanguage\":\"ja\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/npt-lok.com\\\/needle-valve-types\\\/\",\"url\":\"https:\\\/\\\/npt-lok.com\\\/needle-valve-types\\\/\",\"name\":\"Needle valve types\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/npt-lok.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/npt-lok.com\\\/needle-valve-types\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/npt-lok.com\\\/needle-valve-types\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/npt-lok.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/S-6000-psi-needle-valve-3.png\",\"datePublished\":\"2026-05-21T07:25:15+00:00\",\"dateModified\":\"2026-08-18T07:22:28+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/npt-lok.com\\\/needle-valve-types\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/npt-lok.com\\\/needle-valve-types\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/npt-lok.com\\\/needle-valve-types\\\/#primaryimage\",\"url\":\"https:\\\/\\\/npt-lok.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/S-6000-psi-needle-valve-3.png\",\"contentUrl\":\"https:\\\/\\\/npt-lok.com\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/S-6000-psi-needle-valve-3.png\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/npt-lok.com\\\/needle-valve-types\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/npt-lok.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Needle Valve Types and Selection Guide\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/npt-lok.com\\\/#website\",\"url\":\"https:\\\/\\\/npt-lok.com\\\/\",\"name\":\"NPTLOK Instrumentation Tube Fittings and Valves\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/npt-lok.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/npt-lok.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/npt-lok.com\\\/#organization\",\"name\":\"NPTLOK Instrumentation Tube Fittings and Valves\",\"url\":\"https:\\\/\\\/npt-lok.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/npt-lok.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/npt-lok.com\\\/wp-content\\\/uploads\\\/2022\\\/08\\\/cropped-cropped-NPT-LOK\u9ed1\u767d-e1787037014570.png\",\"contentUrl\":\"https:\\\/\\\/npt-lok.com\\\/wp-content\\\/uploads\\\/2022\\\/08\\\/cropped-cropped-NPT-LOK\u9ed1\u767d-e1787037014570.png\",\"width\":260,\"height\":85,\"caption\":\"NPTLOK Instrumentation Tube Fittings and Valves\"},\"image\":{\"@id\":\"https:\\\/\\\/npt-lok.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/npt-lok.com\\\/#\\\/schema\\\/person\\\/952fa6592fb0069202b037e7605d4e19\",\"name\":\"NPTLOK\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/786b349f66bfff9c6f962d1bcfdeec2a96c09c6f1e30f21f2e6c2f994b4d7f5f?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/786b349f66bfff9c6f962d1bcfdeec2a96c09c6f1e30f21f2e6c2f994b4d7f5f?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/786b349f66bfff9c6f962d1bcfdeec2a96c09c6f1e30f21f2e6c2f994b4d7f5f?s=96&d=mm&r=g\",\"caption\":\"NPTLOK\"},\"url\":\"https:\\\/\\\/npt-lok.com\\\/ja\\\/author\\\/dp_admin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Needle valve types","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/npt-lok.com\/ja\/needle-valve-types\/","og_locale":"ja_JP","og_type":"article","og_title":"Needle valve types","og_description":"Needle valves are typically classified into several types, which are utilized for particular functions. And you may want to know what features you need to take into account when choosing one. Here is a brief introduction of each type and a selection guide. Main Types of Needle Valves Straight Needle Valve.\u00a0 This type of needle [&hellip;]","og_url":"https:\/\/npt-lok.com\/ja\/needle-valve-types\/","og_site_name":"NPTLOK Instrumentation Tube Fittings and Valves","article_published_time":"2026-05-21T07:25:15+00:00","article_modified_time":"2026-08-18T07:22:28+00:00","og_image":[{"width":486,"height":486,"url":"https:\/\/npt-lok.com\/wp-content\/uploads\/2026\/04\/S-6000-psi-needle-valve-3.png","type":"image\/png"}],"author":"NPTLOK","twitter_card":"summary_large_image","twitter_misc":{"\u57f7\u7b46\u8005":"NPTLOK","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"6\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/npt-lok.com\/needle-valve-types\/#article","isPartOf":{"@id":"https:\/\/npt-lok.com\/needle-valve-types\/"},"author":{"name":"NPTLOK","@id":"https:\/\/npt-lok.com\/#\/schema\/person\/952fa6592fb0069202b037e7605d4e19"},"headline":"Needle Valve Types and Selection Guide","datePublished":"2026-05-21T07:25:15+00:00","dateModified":"2026-08-18T07:22:28+00:00","mainEntityOfPage":{"@id":"https:\/\/npt-lok.com\/needle-valve-types\/"},"wordCount":1029,"publisher":{"@id":"https:\/\/npt-lok.com\/#organization"},"image":{"@id":"https:\/\/npt-lok.com\/needle-valve-types\/#primaryimage"},"thumbnailUrl":"https:\/\/npt-lok.com\/wp-content\/uploads\/2026\/04\/S-6000-psi-needle-valve-3.png","articleSection":["Blog"],"inLanguage":"ja"},{"@type":"WebPage","@id":"https:\/\/npt-lok.com\/needle-valve-types\/","url":"https:\/\/npt-lok.com\/needle-valve-types\/","name":"Needle valve types","isPartOf":{"@id":"https:\/\/npt-lok.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/npt-lok.com\/needle-valve-types\/#primaryimage"},"image":{"@id":"https:\/\/npt-lok.com\/needle-valve-types\/#primaryimage"},"thumbnailUrl":"https:\/\/npt-lok.com\/wp-content\/uploads\/2026\/04\/S-6000-psi-needle-valve-3.png","datePublished":"2026-05-21T07:25:15+00:00","dateModified":"2026-08-18T07:22:28+00:00","breadcrumb":{"@id":"https:\/\/npt-lok.com\/needle-valve-types\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/npt-lok.com\/needle-valve-types\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/npt-lok.com\/needle-valve-types\/#primaryimage","url":"https:\/\/npt-lok.com\/wp-content\/uploads\/2026\/04\/S-6000-psi-needle-valve-3.png","contentUrl":"https:\/\/npt-lok.com\/wp-content\/uploads\/2026\/04\/S-6000-psi-needle-valve-3.png"},{"@type":"BreadcrumbList","@id":"https:\/\/npt-lok.com\/needle-valve-types\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/npt-lok.com\/"},{"@type":"ListItem","position":2,"name":"Needle Valve Types and Selection Guide"}]},{"@type":"WebSite","@id":"https:\/\/npt-lok.com\/#website","url":"https:\/\/npt-lok.com\/","name":"NPTLOK\u8a08\u88c5\u7528\u30c1\u30e5\u30fc\u30d6\u7d99\u624b\u304a\u3088\u3073\u30d0\u30eb\u30d6","description":"","publisher":{"@id":"https:\/\/npt-lok.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/npt-lok.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Organization","@id":"https:\/\/npt-lok.com\/#organization","name":"NPTLOK\u8a08\u88c5\u7528\u30c1\u30e5\u30fc\u30d6\u7d99\u624b\u304a\u3088\u3073\u30d0\u30eb\u30d6","url":"https:\/\/npt-lok.com\/","logo":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/npt-lok.com\/#\/schema\/logo\/image\/","url":"https:\/\/npt-lok.com\/wp-content\/uploads\/2022\/08\/cropped-cropped-NPT-LOK\u9ed1\u767d-e1787037014570.png","contentUrl":"https:\/\/npt-lok.com\/wp-content\/uploads\/2022\/08\/cropped-cropped-NPT-LOK\u9ed1\u767d-e1787037014570.png","width":260,"height":85,"caption":"NPTLOK Instrumentation Tube Fittings and Valves"},"image":{"@id":"https:\/\/npt-lok.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/npt-lok.com\/#\/schema\/person\/952fa6592fb0069202b037e7605d4e19","name":"NPTLOK","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/786b349f66bfff9c6f962d1bcfdeec2a96c09c6f1e30f21f2e6c2f994b4d7f5f?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/786b349f66bfff9c6f962d1bcfdeec2a96c09c6f1e30f21f2e6c2f994b4d7f5f?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/786b349f66bfff9c6f962d1bcfdeec2a96c09c6f1e30f21f2e6c2f994b4d7f5f?s=96&d=mm&r=g","caption":"NPTLOK"},"url":"https:\/\/npt-lok.com\/ja\/author\/dp_admin\/"}]}},"_links":{"self":[{"href":"https:\/\/npt-lok.com\/ja\/wp-json\/wp\/v2\/posts\/15065","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/npt-lok.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/npt-lok.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/npt-lok.com\/ja\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/npt-lok.com\/ja\/wp-json\/wp\/v2\/comments?post=15065"}],"version-history":[{"count":8,"href":"https:\/\/npt-lok.com\/ja\/wp-json\/wp\/v2\/posts\/15065\/revisions"}],"predecessor-version":[{"id":15644,"href":"https:\/\/npt-lok.com\/ja\/wp-json\/wp\/v2\/posts\/15065\/revisions\/15644"}],"wp:attachment":[{"href":"https:\/\/npt-lok.com\/ja\/wp-json\/wp\/v2\/media?parent=15065"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/npt-lok.com\/ja\/wp-json\/wp\/v2\/categories?post=15065"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/npt-lok.com\/ja\/wp-json\/wp\/v2\/tags?post=15065"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}