{"id":15206,"date":"2026-06-04T01:30:07","date_gmt":"2026-06-04T01:30:07","guid":{"rendered":"https:\/\/npt-lok.com\/?p=15206"},"modified":"2026-08-18T07:23:11","modified_gmt":"2026-08-18T07:23:11","slug":"manifold-valve-types","status":"publish","type":"post","link":"https:\/\/npt-lok.com\/id\/manifold-valve-types\/","title":{"rendered":"Manifold Valve Types Explained: Classified by Number of Valves and Connection Type"},"content":{"rendered":"<p><span style=\"font-weight: 400;\"><a href=\"https:\/\/npt-lok.com\/id\/katup-manifold\/\">Katup manifold<\/a> on a manifold are typically described in terms of the number of valves in the manifold block, and also by the method of connection to transmitter(s). 2-way, 3-way, or 5-way\uff1f Threaded, or flange\uff1f Not sure which manifold valve you need\uff1f This guide breaks down the types so you can choose with confidence. <\/span><\/p>\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_88 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Daftar isi<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Toggle Table of Content\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">Alihkan<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewbox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewbox=\"0 0 24 24\" version=\"1.2\" baseprofile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1' ><li class='ez-toc-page-1 ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/npt-lok.com\/id\/manifold-valve-types\/#1_Classification_by_Number_of_Valves\" >1. Classification by Number of Valves<\/a><ul class='ez-toc-list-level-5' ><li class='ez-toc-heading-level-5'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/npt-lok.com\/id\/manifold-valve-types\/#2-Way_Manifold_Valve\" >Katup Manifold 2 Arah<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-5'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/npt-lok.com\/id\/manifold-valve-types\/#3-Way_Manifold_Valve\" >3-Way Manifold Valve<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-5'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/npt-lok.com\/id\/manifold-valve-types\/#5-Way_Manifold_Valve\" >5-Way Manifold Valve<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/npt-lok.com\/id\/manifold-valve-types\/#2_Classification_by_Connection_Type\" >2. Classification by Connection Type<\/a><ul class='ez-toc-list-level-5' ><li class='ez-toc-heading-level-5'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/npt-lok.com\/id\/manifold-valve-types\/#Threaded_Connection_Manifolds\" >Threaded Connection Manifolds<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-5'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/npt-lok.com\/id\/manifold-valve-types\/#Flanged_Connection_Manifolds\" >Flanged Connection Manifolds<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/npt-lok.com\/id\/manifold-valve-types\/#FAQ\" >Pertanyaan yang Sering Diajukan (FAQ)<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-4'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/npt-lok.com\/id\/manifold-valve-types\/#Final_Thoughts\" >Final Thoughts<\/a><\/li><\/ul><\/nav><\/div>\n<h4><span class=\"ez-toc-section\" id=\"1_Classification_by_Number_of_Valves\"><\/span><span style=\"font-weight: 400;\">1. Classification by Number of Valves<\/span><span class=\"ez-toc-section-end\"><\/span><\/h4>\n<p><span style=\"font-weight: 400;\">A manifold can be classified based on the number of valves it contains. This includes 2-way, 3-way, 5-way manifolds. As for each type of manifold, it will also be used with a particular type or types of instrument(s).<\/span><\/p>\n<h5><span class=\"ez-toc-section\" id=\"2-Way_Manifold_Valve\"><\/span><a href=\"https:\/\/npt-lok.com\/id\/katup-manifold-2-arah\/\"><span style=\"font-weight: 400;\">Katup Manifold 2 Arah<\/span><\/a><span class=\"ez-toc-section-end\"><\/span><\/h5>\n<p><span style=\"font-weight: 400;\">Used for: Gauge pressure transmitters (static pressure measurement)<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Valve functions:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Block valve:\u00a0 to isolate the process from the instruments<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Bleed (vent) valve: The same as above but on the instrument side to release trapped pressure.<\/span><\/li>\n<\/ul>\n<p><span style=\"font-weight: 400;\">How it works\uff1fDuring normal process operation, the block valve is in the open position &amp; the bleed valve in the closed position. To remove the transmitter from service, shut the block valve. Open the bleed valve to safely vent the instrument side of the transmitter. The reading on the transmitter would return to zero, allowing for removal of the transmitter.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">The 2-way manifold is the simplest manifold and is used for isolation of gauge type pressure gauges and\/or transmitters for occasional venting.<\/span><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-12174\" src=\"https:\/\/npt-lok.com\/wp-content\/uploads\/2023\/03\/2-way-manifold-valve-1.jpg\" alt=\"Katup manifold 2 arah\" width=\"370\" height=\"370\" srcset=\"https:\/\/npt-lok.com\/wp-content\/uploads\/2023\/03\/2-way-manifold-valve-1.jpg 370w, https:\/\/npt-lok.com\/wp-content\/uploads\/2023\/03\/2-way-manifold-valve-1-150x150.jpg 150w\" sizes=\"auto, (max-width: 370px) 100vw, 370px\" \/><\/p>\n<h5><span class=\"ez-toc-section\" id=\"3-Way_Manifold_Valve\"><\/span><a href=\"https:\/\/npt-lok.com\/id\/katup-manifold-3-arah\/\"><span style=\"font-weight: 400;\">3-Way Manifold Valve<\/span><\/a><span class=\"ez-toc-section-end\"><\/span><\/h5>\n<p><span style=\"font-weight: 400;\">Used for: Differential pressure transmitters (flow, level and pressure drop measurement).<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Valve functions:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">2 Block Valves, one on the high side of the transmitter and one on the low side.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">One equalizing valve between the two block valves<\/span><\/li>\n<\/ul>\n<p><span style=\"font-weight: 400;\">How does it work? In normal operation, the transmitter is shown fully operational with both block valves open, and the equalizing valve closed.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">To check the zero or remove the transmitter:<\/span><\/p>\n<ol>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Open the equalising or bell mouthed valve to equalise the pressure on both sides of the transmitter.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Next close both block valves. The transmitter is now isolated from the process. The transmitter now reads zero.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">The transmitter can then be taken out of service and recalibrated as necessary.<\/span><\/li>\n<\/ol>\n<p><span style=\"font-weight: 400;\">The 3-way manifold valve is typically used for differential pressure transmitters used in flow measurement, level measurement and in the monitoring of pressure drop across filters.<\/span><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-11830\" src=\"https:\/\/npt-lok.com\/wp-content\/uploads\/2022\/11\/Female-thread-3-way-manifold-valve.jpg\" alt=\"Katup manifold 3 arah ulir betina\" width=\"370\" height=\"370\" srcset=\"https:\/\/npt-lok.com\/wp-content\/uploads\/2022\/11\/Female-thread-3-way-manifold-valve.jpg 370w, https:\/\/npt-lok.com\/wp-content\/uploads\/2022\/11\/Female-thread-3-way-manifold-valve-150x150.jpg 150w\" sizes=\"auto, (max-width: 370px) 100vw, 370px\" \/><\/p>\n<h5><span class=\"ez-toc-section\" id=\"5-Way_Manifold_Valve\"><\/span><a href=\"https:\/\/npt-lok.com\/id\/katup-manifold\/katup-manifold-5-arah\/\"><span style=\"font-weight: 400;\">5-Way Manifold Valve<\/span><\/a><span class=\"ez-toc-section-end\"><\/span><\/h5>\n<p><span style=\"font-weight: 400;\">Differential pressure transmitters that have to be calibrated or tested while the process is running.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Valve functions:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Two block valves (high side and low side)<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">One equalizing valve<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Two bleed\/vent valves (one for each side)<\/span><\/li>\n<\/ul>\n<p><span style=\"font-weight: 400;\">How it works\uff1aThe 5-way manifold does everything the 3-way manifold does, plus you have the additional feature of dedicated bleed valves. This allows you to:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Vent each side of the transmitter separately.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Allow for connection of a pressure calibration device to one side of the transmitter while the process is flowing on the other side of the transmitter.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Perform 3-point or 5-point calibrations.<\/span><\/li>\n<\/ul>\n<p><span style=\"font-weight: 400;\">The two bleed\/vent valves on a 5-way manifold are typically 1\/4\u201d NPT in size and are plugged at the end. A pressure generator or a calibration device can be connected at these ports as required.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">In many industries the 5-way manifold is the most common type of manifold used in conjunction with differential pressure transmitters.<\/span><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-12510\" src=\"https:\/\/npt-lok.com\/wp-content\/uploads\/2023\/05\/5-way-manifold-valve.jpg\" alt=\"Katup manifold 5 arah\" width=\"370\" height=\"370\" srcset=\"https:\/\/npt-lok.com\/wp-content\/uploads\/2023\/05\/5-way-manifold-valve.jpg 370w, https:\/\/npt-lok.com\/wp-content\/uploads\/2023\/05\/5-way-manifold-valve-150x150.jpg 150w\" sizes=\"auto, (max-width: 370px) 100vw, 370px\" \/><\/p>\n<h4><span class=\"ez-toc-section\" id=\"2_Classification_by_Connection_Type\"><\/span><span style=\"font-weight: 400;\">2. Classification by Connection Type<\/span><span class=\"ez-toc-section-end\"><\/span><\/h4>\n<p><span style=\"font-weight: 400;\">In addition to the number of valves a manifold can have, a manifold can also be classified based on the connection type to the differential pressure transmitter and the process connections.<\/span><\/p>\n<h5><span class=\"ez-toc-section\" id=\"Threaded_Connection_Manifolds\"><\/span><span style=\"font-weight: 400;\">Threaded Connection Manifolds<\/span><span class=\"ez-toc-section-end\"><\/span><\/h5>\n<p><span style=\"font-weight: 400;\">The manifold connects directly to the transmitter and process lines using threaded ports. This is the most common type.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Advantages\uff1a<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Simple and compact without extra flanges and gaskets.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">This is very easy to install, as it can be screwed into position.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Lower cost than flanged manifolds.<\/span><\/li>\n<\/ul>\n<p><span style=\"font-weight: 400;\">Typical thread standards\uff1a<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">NPT (National Pipe Thread) : most used in North America.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">BSPT or BSPP: They are commonly used in Europe, Asia and the Middle East and also in other parts of the world.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Metric threads: for OEM equipment<\/span><\/li>\n<\/ul>\n<p><span style=\"font-weight: 400;\">Common port sizes\uff1a<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Process connections \u2013 1\/2\u201d NPT or 1\/4\u201c NPT<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Instrument connections are typically the same connection size as the transmitter for which you are purchasing a manifold (e.g. 1\/2\u201d NPT or M20\u00d71.5).<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Bleed\/vent ports \u2013 1\/4\u201c NPT<\/span><\/li>\n<\/ul>\n<p><span style=\"font-weight: 400;\">Threaded manifolds are generally suited for normal industrial applications at moderate pressures. While Flanged manifolds are recommended for high pressure or high temperature applications.<\/span><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-12168\" src=\"https:\/\/npt-lok.com\/wp-content\/uploads\/2023\/03\/Female-thread-2-way-manifold-valve.jpg\" alt=\"Katup manifold 2 arah ulir betina\" width=\"370\" height=\"370\" srcset=\"https:\/\/npt-lok.com\/wp-content\/uploads\/2023\/03\/Female-thread-2-way-manifold-valve.jpg 370w, https:\/\/npt-lok.com\/wp-content\/uploads\/2023\/03\/Female-thread-2-way-manifold-valve-150x150.jpg 150w\" sizes=\"auto, (max-width: 370px) 100vw, 370px\" \/><\/p>\n<h5><span class=\"ez-toc-section\" id=\"Flanged_Connection_Manifolds\"><\/span><span style=\"font-weight: 400;\">Flanged Connection Manifolds<\/span><span class=\"ez-toc-section-end\"><\/span><\/h5>\n<p><span style=\"font-weight: 400;\">Flanged Connection Manifolds are attached to a transmitter or pipe work using flanges which are bolted together with a gasket in the middle.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Advantages\uff1a<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Better for high-pressure and high-temperature service<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Stronger and more rigid than threaded connections<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Alignment and bolt up in the field is easier.<\/span><\/li>\n<\/ul>\n<p><span style=\"font-weight: 400;\">Disadvantages\uff1a<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Larger and heavier than threaded manifolds<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Higher cost<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">More parts: flanges, bolts, nuts, gaskets<\/span><\/li>\n<\/ul>\n<p><span style=\"font-weight: 400;\">Typical flange standards\uff1a<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">ASME B16.5: Typically used in North America. (Class 150, 300, 600, etc.)<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">PN16, PN40, etc. according to EN 1092-1 in Europe.<\/span><\/li>\n<\/ul>\n<p><span style=\"font-weight: 400;\">Flange facing types\uff1a<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">RF (Raised Face) :\u00a0 most common<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">RTJ (Ring Type Joint) : typically used for high-pressure gas service applications.<\/span><\/li>\n<\/ul>\n<p><span style=\"font-weight: 400;\">Flanged manifolds are often used in:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">High-pressure steam systems<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">High-temperature process lines<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Refineries and petrochemical plants<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Pembangkit listrik<\/span><\/li>\n<\/ul>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-12509\" src=\"https:\/\/npt-lok.com\/wp-content\/uploads\/2023\/05\/Flange-5-way-manifold-valve.jpg\" alt=\"Katup manifold 5 arah flensa\" width=\"370\" height=\"370\" srcset=\"https:\/\/npt-lok.com\/wp-content\/uploads\/2023\/05\/Flange-5-way-manifold-valve.jpg 370w, https:\/\/npt-lok.com\/wp-content\/uploads\/2023\/05\/Flange-5-way-manifold-valve-150x150.jpg 150w\" sizes=\"auto, (max-width: 370px) 100vw, 370px\" \/><\/p>\n<h4><span class=\"ez-toc-section\" id=\"FAQ\"><\/span><span style=\"font-weight: 400;\">Pertanyaan yang Sering Diajukan (FAQ)<\/span><span class=\"ez-toc-section-end\"><\/span><\/h4>\n<p><span style=\"font-weight: 400;\">Q1. What material are manifold valves typically made of\uff1f<\/span><\/p>\n<p><span style=\"font-weight: 400;\">316 Stainless Steel is the typical material used for manifold valves as it can deal with the majority of media and environments. Occasionally Monel is used for seawater \/ sour gas applications and in extreme cases of corrosion with acids such as Hydrochloric Acid then Hastings C-276 is typically used.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Q2. Do I need to use thread sealant on a flanged manifold valve\uff1f<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Flanged connections are sealed with a gasket between the faces of the flanges and as such, thread sealant should never be used on the threads of the bolts of a flange connection. The appropriate gasket material must be chosen for the process media and the process temperature.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Q3. What is the difference between a bleed valve and a vent valve\uff1f<\/span><\/p>\n<p><span style=\"font-weight: 400;\">A Bleed Valve is equal to a Vent Valve. These two names are used for the same type of valves in different industries. A Bleed Valve or Vent Valve is used to release trapped pressure from the instrument side.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Q4. How do I know if my transmitter needs a 2-way, 3-way, or 5-way manifold\uff1f<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Count the pressure ports on your transmitter. One pressure port \u2192 gauge pressure transmitter \u2192 2-way manifold. Two pressure ports (high and low) \u2192 differential pressure transmitter \u2192 3-way or 5-way manifold. Need calibration ports\uff1f \u2192 5-way manifold.<\/span><\/p>\n<h4><span class=\"ez-toc-section\" id=\"Final_Thoughts\"><\/span><span style=\"font-weight: 400;\">Final Thoughts<\/span><span class=\"ez-toc-section-end\"><\/span><\/h4>\n<p><span style=\"font-weight: 400;\">A manifold valve is an extremely valuable piece of equipment to make connections to your instruments a lot easier. Having all the individual valves for all the instruments in one area greatly reduces the amount of potential leak points and makes maintenance a whole lot easier.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Most of the time, the choice comes down to your instrument type and connection requirements. Still not sure which manifold valve you need\uff1f<a href=\"https:\/\/npt-lok.com\/id\/hubungi-untuk-penawaran-harga\/\"> Hubungi kami<\/a>. We will help you pick the right one.<\/span><\/p>","protected":false},"excerpt":{"rendered":"<p>Manifold valves on a manifold are typically described in terms of the number of valves in the manifold block, and also by the method of connection to transmitter(s). 2-way, 3-way, or 5-way\uff1f Threaded, or flange\uff1f Not sure which manifold valve you need\uff1f This guide breaks down the types so you can choose with confidence. 1. [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"default","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[1],"tags":[],"class_list":["post-15206","post","type-post","status-publish","format-standard","hentry","category-blog"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.7 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Manifold Valve Types Explained: Classified by Number of Valves and Connection Type - NPTLOK Instrumentation Tube Fittings and Valves<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/npt-lok.com\/id\/manifold-valve-types\/\" \/>\n<meta property=\"og:locale\" content=\"id_ID\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Manifold Valve Types Explained: Classified by Number of Valves and Connection Type - NPTLOK Instrumentation Tube Fittings and Valves\" \/>\n<meta property=\"og:description\" content=\"Manifold valves on a manifold are typically described in terms of the number of valves in the manifold block, and also by the method of connection to transmitter(s). 2-way, 3-way, or 5-way\uff1f Threaded, or flange\uff1f Not sure which manifold valve you need\uff1f This guide breaks down the types so you can choose with confidence. 1. [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/npt-lok.com\/id\/manifold-valve-types\/\" \/>\n<meta property=\"og:site_name\" content=\"NPTLOK Instrumentation Tube Fittings and Valves\" \/>\n<meta property=\"article:published_time\" content=\"2026-06-04T01:30:07+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-08-18T07:23:11+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/npt-lok.com\/wp-content\/uploads\/2023\/03\/2-way-manifold-valve-1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"370\" \/>\n\t<meta property=\"og:image:height\" content=\"370\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"NPTLOK\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Ditulis oleh\" \/>\n\t<meta name=\"twitter:data1\" content=\"NPTLOK\" \/>\n\t<meta name=\"twitter:label2\" content=\"Estimasi waktu membaca\" \/>\n\t<meta name=\"twitter:data2\" content=\"6 menit\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/npt-lok.com\\\/manifold-valve-types\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/npt-lok.com\\\/manifold-valve-types\\\/\"},\"author\":{\"name\":\"NPTLOK\",\"@id\":\"https:\\\/\\\/npt-lok.com\\\/#\\\/schema\\\/person\\\/952fa6592fb0069202b037e7605d4e19\"},\"headline\":\"Manifold Valve Types Explained: Classified by Number of Valves and Connection Type\",\"datePublished\":\"2026-06-04T01:30:07+00:00\",\"dateModified\":\"2026-08-18T07:23:11+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/npt-lok.com\\\/manifold-valve-types\\\/\"},\"wordCount\":1139,\"publisher\":{\"@id\":\"https:\\\/\\\/npt-lok.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/npt-lok.com\\\/manifold-valve-types\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/npt-lok.com\\\/wp-content\\\/uploads\\\/2023\\\/03\\\/2-way-manifold-valve-1.jpg\",\"articleSection\":[\"Blog\"],\"inLanguage\":\"id\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/npt-lok.com\\\/manifold-valve-types\\\/\",\"url\":\"https:\\\/\\\/npt-lok.com\\\/manifold-valve-types\\\/\",\"name\":\"Manifold Valve Types Explained: Classified by Number of Valves and Connection Type - NPTLOK Instrumentation Tube Fittings and Valves\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/npt-lok.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/npt-lok.com\\\/manifold-valve-types\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/npt-lok.com\\\/manifold-valve-types\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/npt-lok.com\\\/wp-content\\\/uploads\\\/2023\\\/03\\\/2-way-manifold-valve-1.jpg\",\"datePublished\":\"2026-06-04T01:30:07+00:00\",\"dateModified\":\"2026-08-18T07:23:11+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/npt-lok.com\\\/manifold-valve-types\\\/#breadcrumb\"},\"inLanguage\":\"id\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/npt-lok.com\\\/manifold-valve-types\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"id\",\"@id\":\"https:\\\/\\\/npt-lok.com\\\/manifold-valve-types\\\/#primaryimage\",\"url\":\"https:\\\/\\\/npt-lok.com\\\/wp-content\\\/uploads\\\/2023\\\/03\\\/2-way-manifold-valve-1.jpg\",\"contentUrl\":\"https:\\\/\\\/npt-lok.com\\\/wp-content\\\/uploads\\\/2023\\\/03\\\/2-way-manifold-valve-1.jpg\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/npt-lok.com\\\/manifold-valve-types\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/npt-lok.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Manifold Valve Types Explained: Classified by Number of Valves and Connection Type\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/npt-lok.com\\\/#website\",\"url\":\"https:\\\/\\\/npt-lok.com\\\/\",\"name\":\"NPTLOK Instrumentation Tube Fittings and Valves\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/npt-lok.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/npt-lok.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"id\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/npt-lok.com\\\/#organization\",\"name\":\"NPTLOK Instrumentation Tube Fittings and Valves\",\"url\":\"https:\\\/\\\/npt-lok.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"id\",\"@id\":\"https:\\\/\\\/npt-lok.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/npt-lok.com\\\/wp-content\\\/uploads\\\/2022\\\/08\\\/cropped-cropped-NPT-LOK\u9ed1\u767d-e1787037014570.png\",\"contentUrl\":\"https:\\\/\\\/npt-lok.com\\\/wp-content\\\/uploads\\\/2022\\\/08\\\/cropped-cropped-NPT-LOK\u9ed1\u767d-e1787037014570.png\",\"width\":260,\"height\":85,\"caption\":\"NPTLOK Instrumentation Tube Fittings and Valves\"},\"image\":{\"@id\":\"https:\\\/\\\/npt-lok.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/npt-lok.com\\\/#\\\/schema\\\/person\\\/952fa6592fb0069202b037e7605d4e19\",\"name\":\"NPTLOK\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"id\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/786b349f66bfff9c6f962d1bcfdeec2a96c09c6f1e30f21f2e6c2f994b4d7f5f?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/786b349f66bfff9c6f962d1bcfdeec2a96c09c6f1e30f21f2e6c2f994b4d7f5f?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/786b349f66bfff9c6f962d1bcfdeec2a96c09c6f1e30f21f2e6c2f994b4d7f5f?s=96&d=mm&r=g\",\"caption\":\"NPTLOK\"},\"url\":\"https:\\\/\\\/npt-lok.com\\\/id\\\/author\\\/dp_admin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Manifold Valve Types Explained: Classified by Number of Valves and Connection Type - NPTLOK Instrumentation Tube Fittings and Valves","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/npt-lok.com\/id\/manifold-valve-types\/","og_locale":"id_ID","og_type":"article","og_title":"Manifold Valve Types Explained: Classified by Number of Valves and Connection Type - NPTLOK Instrumentation Tube Fittings and Valves","og_description":"Manifold valves on a manifold are typically described in terms of the number of valves in the manifold block, and also by the method of connection to transmitter(s). 2-way, 3-way, or 5-way\uff1f Threaded, or flange\uff1f Not sure which manifold valve you need\uff1f This guide breaks down the types so you can choose with confidence. 1. [&hellip;]","og_url":"https:\/\/npt-lok.com\/id\/manifold-valve-types\/","og_site_name":"NPTLOK Instrumentation Tube Fittings and Valves","article_published_time":"2026-06-04T01:30:07+00:00","article_modified_time":"2026-08-18T07:23:11+00:00","og_image":[{"width":370,"height":370,"url":"https:\/\/npt-lok.com\/wp-content\/uploads\/2023\/03\/2-way-manifold-valve-1.jpg","type":"image\/jpeg"}],"author":"NPTLOK","twitter_card":"summary_large_image","twitter_misc":{"Ditulis oleh":"NPTLOK","Estimasi waktu membaca":"6 menit"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/npt-lok.com\/manifold-valve-types\/#article","isPartOf":{"@id":"https:\/\/npt-lok.com\/manifold-valve-types\/"},"author":{"name":"NPTLOK","@id":"https:\/\/npt-lok.com\/#\/schema\/person\/952fa6592fb0069202b037e7605d4e19"},"headline":"Manifold Valve Types Explained: Classified by Number of Valves and Connection Type","datePublished":"2026-06-04T01:30:07+00:00","dateModified":"2026-08-18T07:23:11+00:00","mainEntityOfPage":{"@id":"https:\/\/npt-lok.com\/manifold-valve-types\/"},"wordCount":1139,"publisher":{"@id":"https:\/\/npt-lok.com\/#organization"},"image":{"@id":"https:\/\/npt-lok.com\/manifold-valve-types\/#primaryimage"},"thumbnailUrl":"https:\/\/npt-lok.com\/wp-content\/uploads\/2023\/03\/2-way-manifold-valve-1.jpg","articleSection":["Blog"],"inLanguage":"id"},{"@type":"WebPage","@id":"https:\/\/npt-lok.com\/manifold-valve-types\/","url":"https:\/\/npt-lok.com\/manifold-valve-types\/","name":"Manifold Valve Types Explained: Classified by Number of Valves and Connection Type - NPTLOK Instrumentation Tube Fittings and Valves","isPartOf":{"@id":"https:\/\/npt-lok.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/npt-lok.com\/manifold-valve-types\/#primaryimage"},"image":{"@id":"https:\/\/npt-lok.com\/manifold-valve-types\/#primaryimage"},"thumbnailUrl":"https:\/\/npt-lok.com\/wp-content\/uploads\/2023\/03\/2-way-manifold-valve-1.jpg","datePublished":"2026-06-04T01:30:07+00:00","dateModified":"2026-08-18T07:23:11+00:00","breadcrumb":{"@id":"https:\/\/npt-lok.com\/manifold-valve-types\/#breadcrumb"},"inLanguage":"id","potentialAction":[{"@type":"ReadAction","target":["https:\/\/npt-lok.com\/manifold-valve-types\/"]}]},{"@type":"ImageObject","inLanguage":"id","@id":"https:\/\/npt-lok.com\/manifold-valve-types\/#primaryimage","url":"https:\/\/npt-lok.com\/wp-content\/uploads\/2023\/03\/2-way-manifold-valve-1.jpg","contentUrl":"https:\/\/npt-lok.com\/wp-content\/uploads\/2023\/03\/2-way-manifold-valve-1.jpg"},{"@type":"BreadcrumbList","@id":"https:\/\/npt-lok.com\/manifold-valve-types\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/npt-lok.com\/"},{"@type":"ListItem","position":2,"name":"Manifold Valve Types Explained: Classified by Number of Valves and Connection Type"}]},{"@type":"WebSite","@id":"https:\/\/npt-lok.com\/#website","url":"https:\/\/npt-lok.com\/","name":"Alat Kelengkapan Tabung dan Katup Instrumentasi NPTLOK","description":"","publisher":{"@id":"https:\/\/npt-lok.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/npt-lok.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"id"},{"@type":"Organization","@id":"https:\/\/npt-lok.com\/#organization","name":"Alat Kelengkapan Tabung dan Katup Instrumentasi NPTLOK","url":"https:\/\/npt-lok.com\/","logo":{"@type":"ImageObject","inLanguage":"id","@id":"https:\/\/npt-lok.com\/#\/schema\/logo\/image\/","url":"https:\/\/npt-lok.com\/wp-content\/uploads\/2022\/08\/cropped-cropped-NPT-LOK\u9ed1\u767d-e1787037014570.png","contentUrl":"https:\/\/npt-lok.com\/wp-content\/uploads\/2022\/08\/cropped-cropped-NPT-LOK\u9ed1\u767d-e1787037014570.png","width":260,"height":85,"caption":"NPTLOK Instrumentation Tube Fittings and Valves"},"image":{"@id":"https:\/\/npt-lok.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/npt-lok.com\/#\/schema\/person\/952fa6592fb0069202b037e7605d4e19","name":"NPTLOK","image":{"@type":"ImageObject","inLanguage":"id","@id":"https:\/\/secure.gravatar.com\/avatar\/786b349f66bfff9c6f962d1bcfdeec2a96c09c6f1e30f21f2e6c2f994b4d7f5f?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/786b349f66bfff9c6f962d1bcfdeec2a96c09c6f1e30f21f2e6c2f994b4d7f5f?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/786b349f66bfff9c6f962d1bcfdeec2a96c09c6f1e30f21f2e6c2f994b4d7f5f?s=96&d=mm&r=g","caption":"NPTLOK"},"url":"https:\/\/npt-lok.com\/id\/author\/dp_admin\/"}]}},"_links":{"self":[{"href":"https:\/\/npt-lok.com\/id\/wp-json\/wp\/v2\/posts\/15206","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/npt-lok.com\/id\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/npt-lok.com\/id\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/npt-lok.com\/id\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/npt-lok.com\/id\/wp-json\/wp\/v2\/comments?post=15206"}],"version-history":[{"count":9,"href":"https:\/\/npt-lok.com\/id\/wp-json\/wp\/v2\/posts\/15206\/revisions"}],"predecessor-version":[{"id":15645,"href":"https:\/\/npt-lok.com\/id\/wp-json\/wp\/v2\/posts\/15206\/revisions\/15645"}],"wp:attachment":[{"href":"https:\/\/npt-lok.com\/id\/wp-json\/wp\/v2\/media?parent=15206"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/npt-lok.com\/id\/wp-json\/wp\/v2\/categories?post=15206"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/npt-lok.com\/id\/wp-json\/wp\/v2\/tags?post=15206"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}